FORMAWALL DIMENSION SERIES: 3" (76mm) VERTICAL FLAT | |
|

General & Technical Data
Features
- Horizontal (FWDS-H) and vertical (FWDS-V) designs available
- A variety of reveal, thickness and profile configurations are available, providing design flexibility and options for exterior walls
- Concealed clips and fasteners plus dry gaskets and concealed sealants provide a clean, uninterrupted appearance while minimizing exterior dirt streaking and staining
- Factory foamed for dependable thermal performance
- Profiled and flat panels integrate with CENTRIA Formavue® window systems, and most glass wall and window systems
- Rainscreen Principle horizontal joinery provides superior weather resistance
- Pressure equalization achieved through vents along the panel length where required
- Factory-formed sheet metal flashing or extruded aluminum trim available
- Can be easily curved or formed
- Panel mitering permits clean, sharp corners, beam and column wraps
- Trimless ends
- Thermal break between face and liner
- Lightweight - easy to handle and install; less framing required
- Stainless, striated, smooth and embossed surface treatments available
Panel Description
Metal
- Standard - 22/26 gage [0.76mm / 0.48mm], 22/22 gage [0.76mm / 0.76mm]
- Optional gages available, consult CENTRIA
- G-90 (Z275) galvanized steel; optional stainless steel or aluminum available, consult CENTRIA
Surface Finish
- Exterior - Non-directional embossing, smooth or striated
- Interior (liner) - Directional embossing, planked if 22 gage [0.76mm] or lighter
Joinery (with concealed fasteners)
- Vertical - Double tongue-and-groove
- Horizontal - Rainscreen Principle
Panel Width
- Standard - 24", 30", 36" [610mm, 762mm, 914mm]
- Custom - 10" to 40" [254mm to 1016mm]
Panel Length
- Embossed, flat or Embossed, striated face element - 30'-0" [9.14m]
- Smooth, flat face element - 16'0 [4.87m]
- Smooth, striated face element - 20'0" [6.096m]
Panel Depth
- 2", 3" nominal [51mm, 76mm]
"R" Value
- 2" - Depth R14* [51mm – Depth U=0.41 W/m2K]
- 3" - Depth R21* [76mm – Depth U=0.27 W/m2K]
*R-Values are based on ASTM C236 and C518 testing. Air films are included.
Research Reports
- Fire Tests
- UL Tunnel Test, Subject 723, ASTM E84
- Flame Spread 25 max.
- Smoke Developed, 450 max.
- UL Room Corner Test, UL 1715
- Factory Mutual Approval: FM 4880; 50' High Large Scale Corner Test for Unlimited Height Approval for Walls and Ceilings
- SwRI: ASTM E108 Fire Test
- SwRI: Multistory Fire Test, UBC 26-4
- ASTM D2015; BTU Content Test
- ASTM D 1929; Ignition Properties
- UL Fire Wall Designs: 1 hr., 2 hr., 3 hr., U017,U617, U040, U645, U605
CENTRIA Formawall Dimension Series panels have been tested in accordance with requirements of BOCA National Building and ICBO Uniform Building Codes. Contact CENTRIA for more information.
Special Approvals
- City of Los Angeles
- New York City, MEA 64-95-M
- Dade County Approval Miami-Dade County NOA 07-0103.06
Consult CENTRIA for test reports. For actual module dimensions, please reference promotional details located in the right hand column.
|
|
|
| NOTE: The drawing files below are in pdf format. To download the CAD format (dwg or zip), click here to login to the e-CENTRIA Portal |
|
|
 Loading...
|
|
 Loading...
|
|
 Loading...
|
|
|