Economical Kynar®500 Hylar®5000 based coatings that provide good durability and is a good choice for architectural applications.
Performance Characteristics
Reflect the following performance characteristics in accordance with ASTM test procedures:
Dew Cycle Weatherometer Test (ASTM D 366T)
Passes 1,000 hours. Color Change: No more than 5 Δ (Hunter) units. Chalk: Rating no less than 8.
Specular Gloss (ASTM D523 at 60°)
Coating shall have a gloss of 20-35 typical.
Chalking Resistance (ASTM D4214)
Maximum rating of 8.
Color Change (ASTM D2247)
Maximum 5 Δ E (Hunter) units change.
Humidity Test (ASTM D2247)
100% relative humidity at 100°F. Passes 2,000 hours. No blisters.
Salt Spray (ASTM B117)
Passes 1,000 hours with less than 1/16" creepage from scribe. No blisters.
Pollution Resistance Test (ASTM D1308)
10% HCL, 15 minutes – no effect.
20% H2SO4, 18 hours – no effect.
T-Bend (ASTM D4145)
0-T to 2-T no loss of adhesion.
Impact Resistance Test (ASTM D2794)
No loss of adhesion.
Abrasion Resistance Test Falling Sand (ASTM D968)
Liters to expose 5/32 of substrate – 50 liters.
*Polyvinylidene Fluoride (PVDF) coat contains 70% Kynar 500® or Hylar 5000® resin. Kynar 500 is a registered trademark of Elf Atochem North America, Inc. Hylar 5000 is a registered trademark of Ausimont USA, Inc.